JOURNAL OF YANGTZE RIVER SCIENTIFIC RESEARCH INSTI ›› 2017, Vol. 34 ›› Issue (10): 74-78.DOI: 10.11988/ckyyb.20160620

• ROCK SOIL ENGINEERING • Previous Articles     Next Articles

Indoor Model Test on the Bearing Behavior ofPipe Pile under Horizontal Load

QI Le1, SONG Xiu-guang2,3, ZHANG Hong-bo2,3, ZHOU Zhi-dong2,3, YUE Hong-ya2,3   

  1. 1.Shandong Electric Power Engineering Consulting Institute Ltd., Jinan 250013,China;
    2.School of Civil Engineering, Shandong University, Jinan 250061,China;
    3.Shandong Engineering & Technology Research Center for Subgrade Safety,Jinan 250061,China
  • Received:2016-06-16 Revised:2016-08-03 Online:2017-10-01 Published:2017-10-25

Abstract: At present, the design of horizontal bearing pipe pile still takes that of bored pile as reference, resulting in conservative results. In order to reveal the bearing mechanism and obtain the safety reserve value of pile group effect coefficient of pipe pile under horizontal load, we carried out reduced scale model tests. Test results show that: the test values of bearing capacity of single pile and group piles are larger than the calculated results from Technical Code for Building Pile Foundations. The pile group effect coefficients of model test are approximately 1.2 to 1.5 times of the calculated results from Code. The research results are useful for the design of pipe piles under horizontal load.

Key words: pipe pile, horizontal bearing capacity, reduced scale model test, coefficient of pile group effect, values calculated by Code method