Engineering Parameters of Dew Water Collection by Condenser in Gulf Region

CHEN Chi, CHEN Da-wei

Journal of Changjiang River Scientific Research Institute ›› 2017, Vol. 34 ›› Issue (5) : 18-21.

PDF(2679 KB)
PDF(2679 KB)
Journal of Changjiang River Scientific Research Institute ›› 2017, Vol. 34 ›› Issue (5) : 18-21. DOI: 10.11988/ckyyb.20151063
WATER RESOURCES AND ENVIRONMENT

Engineering Parameters of Dew Water Collection by Condenser in Gulf Region

  • CHEN Chi, CHEN Da-wei
Author information +
History +

Abstract

Growing shortage of water resources threatens the survival and development of mankind. Dew water collection, as an approach of water collection with high efficiency and energy saving performance yet no pollution, has been used for a long time due to its feasibility and superiority. Gulf region is a main study area for dew water collection because of its high temperature and humidity. According to features of the gulf region and in association with EES(engineering equation solver) software, the maximum condensation rate is determined under meteorological conditions of relative humidity(RH) 90%, wind speed (v) 8 m/s, and condenser’s sectional area (A) 100 m2. The optimum values of parameters of condenser under minimum power supply are also obtained as follows: condenser diameter (D) 1 m, heat transfer coefficient (U) 1.6, elbow number (N) 50, and superficial area (S) 1 800 m2. The research results could offer reference for dew water collection by condenser in Gulf region.

Key words

dew water collection / gulf region / condensation rate / engineering parameters / engineering equation solver

Cite this article

Download Citations
CHEN Chi, CHEN Da-wei. Engineering Parameters of Dew Water Collection by Condenser in Gulf Region[J]. Journal of Changjiang River Scientific Research Institute. 2017, 34(5): 18-21 https://doi.org/10.11988/ckyyb.20151063

References

[1] LEINER B. Grundlagen Statistischer Methoden[M]. Germany: Oldenbourg Wissenschafts Verlag, 1995.
[2] RAJVANSHI A K.Large Scale Dew Collection as A Source of Fresh Water Supply[J]. Desalination, 1981, 36(3):299-306.
[3] NIKOLAYEV V S,BEYSENS D,GIODA A, et al .Water Recovery from Dew[J].Journal of Hydrology,1996,182(1/4):19-35.
[4] 王廷祥.大气冷凝水化学特性研究[D].上海:复旦大学,2010.
[5] WAHLGREN R V. Atmospheric Water Vapor Processor Designs for Potable Water Production: A Review[J]. Water Research, 2001,35(1):1-22.
[6] 郑伟业.蒸发式冷却器传热传质的试验研究及数值模拟[D].上海:华东理工大学,2012.
[7] 朱冬生,沈家龙.蒸发式冷凝器性能研究及强化[J].制冷学报,2006,27(3):45-49.
[8] SWIFT S A, BOWER A S. Formation and Circulation of Dense Water in the Persian/Arabian Gulf[J].Journal of Geophysical Research Oceans, 2003, 108(S1):1-21.
[9] 郑 静,阎昌琪.核动力装置冷凝器体积的优化设计[J].原子能科学技术,2011,45(1):60-65.