院报 ›› 2017, Vol. 34 ›› Issue (11): 84-88.DOI: 10.11988/ckyyb.20160731

• 岩土工程 • 上一篇    下一篇

基于广义开尔文模型的冻结壁和井壁共同作用下冻结压力解析解

彭世龙1,荣传新1,程桦1,2   

  1. 1.安徽理工大学 土木建筑学院,安徽 淮南 232001;
    2.安徽大学 资源与环境工程学院,合肥 230601
  • 收稿日期:2016-07-18 出版日期:2017-11-01 发布日期:2017-11-19
  • 通讯作者: 荣传新(1968-),男,安徽六安人,教授,博士生导师,博士,主要从事岩土工程和结构工程方面的教学与科研工作,(电话)0554-6633833(电子信箱)chxrong@aust.edu.cn。
  • 作者简介:彭世龙(1991-),男,安徽六安人,博士研究生,主要从事岩土工程结构方面的研究,(电话)15856692871(电子信箱)974860806@qq.com。
  • 基金资助:
    国家自然科学基金项目(51374010,51474004)

Analytical Solution of Freezing Pressure under the Interaction of Freezing Wall and Shaft Lining Based on Generalized Kelvin Model

PENG Shi-long1, RONG Chuan-xin1, CHENG Hua1,2   

  1. 1.School of Civil Engineering and Architecture, Anhui University of Science and Technology, Huainan 232001, China;
    2. School of Resources and Environmental Engineering, Anhui University, Hefei 230601, China
  • Received:2016-07-18 Online:2017-11-01 Published:2017-11-19

摘要: 冻结压力大小是深厚冲积层冻结法凿井外层井壁结构设计计算的重要依据。在冻土单轴蠕变试验基础上,采用广义开尔文流变模型,以及弹性-黏弹性对应原理,建立冻结壁位移场黏弹性方程;然后考虑冻结壁与外层井壁及外围未冻土体的相互作用,推导出了作用于外层井壁上的冻结压力的数学表达式。计算结果表明:在外层井壁砌筑后的前10 d,冻结压力的理论公式计算值与实测结果平均值相差较大,约0.5 MPa;在20 d后,冻结压力趋于稳定,两者差值的绝对值在0.2 MPa以内。总之,冻结压力的理论计算值与实测结果的偏差绝对值在10%以内。因此冻结压力的理论计算公式是比较符合实际的,此公式可为冻结井的外层井壁结构设计提供依据。

关键词: 冻结压力, 广义开尔文流变模型, 冻结法凿井, 冻结壁, 外层井壁

Abstract: Freezing pressure is an important basis for the design and calculation of the outer wall structure of shaft sinking by freezing method in deep alluvium. On the basis of uniaxial creep test of frozen soil, the generalized Kelvin rheological model and the elastic-viscoelastic correspondence principle were adopted to establish the viscoelastic equation of displacement field of frozen wall. Then, the mathematical expression of the freezing pressure acting on the outer shaft lining is deduced by considering the interaction among the frozen wall, the outer shaft lining and the peripheral unfrozen soil. Calculation results show that 1) the calculation value by theoretical formula and from mean measured value of the freezing pressure show a big difference(about 0.5 MPa) in the first ten days after the construction of outer shaft lining masonry; 2) the freezing pressure tends to be stable after 20 days, and the absolute value of the difference between the two is less than 0.2 MPa. In a word, the absolute deviation between the theoretical and calculated values of freezing pressure is less than 10%. The theoretical calculation formula of freezing pressure is quite practical and it could provide basis for the structural design of outer shaft lining of freezing well.

Key words: freezing pressure, generalized Kelvin rheological model, freezing sinking method, frozen wall, outer shaft lining