院报 ›› 2016, Vol. 33 ›› Issue (3): 5-8.DOI: 10.11988/ckyyb.20140868

• 江湖泥沙与治理 • 上一篇    下一篇

比重瓶法测验低含沙量误差分析

吴彰松, 张根广, 梁宗祥, 邢茹   

  1. 西北农林科技大学 水利与建筑工程学院, 陕西 杨凌 712100
  • 收稿日期:2014-10-13 出版日期:2016-03-01 发布日期:2016-03-09
  • 通讯作者: 梁宗祥(1964-),男,陕西宝鸡人,高级工程师, 主要从事水工水力学方面的研究,(电话)13772180505 (电子信箱)liangzx@nwsuaf.edu .cn。
  • 作者简介:吴彰松(1992-),男,河南信阳人,硕士研究生,主要从事水利水电工程研究,(电话) 15249188271(电子信箱)wuzs812@163.com。
  • 基金资助:
    国家自然科学基金项目(51279170)

Error Analysis of Low Sediment Concentration Measured by Pycnometer Method

WU Zhang-song , ZHANG Gen-guang , LIANG Zong-xiang, XING Ru   

  1. College of Water Resources and Architectural Engineering, Northwest A&F University, Yangling 712100, China
  • Received:2014-10-13 Online:2016-03-01 Published:2016-03-09

摘要: 在河流水文测验、河工模型试验、水质评价及工农业取水中,通常采用比重瓶法测验含沙量。在含沙量较小时,因水中溶解质含量较大,用比重瓶法测验得到的含沙量往往大于实际含沙量,但测验者常常怀疑测验过程或测验仪器出现误差,而忽略其真正原因。通过某城市供水沉沙池试验的含沙量测验发现,影响低含沙量测验误差的潜在原因就是浑水中溶解质含量,它对含沙量的影响远远大于水体自身含沙量;此外,温度测验误差对含沙量的影响较大,并且含沙量越小,温度测验误差对含沙量的影响越大。基于此,提出了比重瓶法测验低含沙量的改进方法,得到了与烘干法基本一致的测验结果,为低含沙量测验提供了一些借鉴和参考。

关键词: 比重瓶法, 低含沙量, 误差影响因素, 温度, 溶解质

Abstract: Pycnometer method has been widely used in sediment concentration measurements such as river hydrological measurement, model test of river engineering, evaluation of water quality and water intake in industry and agriculture. However, when sediment concentration is low, the sediment concentration measured by pycnometer method is usually greater than the actual value because the content of dissolved matter is big. In face of such phenomenon, test engineers often doubt error of test instruments or test process, but can’t find the real reasons. Through the sediment concentration measurement of desilting basin test of water supply in a city, we found that the content of dissolved matter in the water is crucial to the measurement error of low sediment concentration; nevertheless, temperature greatly affects sediment concentration, and the smaller the sediment concentration is, the bigger the effect of temperature error is. On this basis, we put forward the improved pycnometer method to measure low sediment concentration, and test results by the method is basically consistent with those by drying method. Finally, it can provide reference for test with low sediment concentration.

Key words: pycnometer method, low sediment concentration, influencing factors of error, temperature, dissolved matter

中图分类号: 

Baidu
map